McCarran International Airport - Terminal 3 & D Wing

LW Engineering performed pipe stress analysis on the proposed hydronic pipe system. Long runs of large pipe with expansion joints created high stress loads. Our stress analysis pinpointed those loads, allowing proper support and anchorage to be installed with the pipe. Compliance with ASME B31.1 was assured and possible failures were averted.